TR 0301 U differential temperature controller

 

The model TR 0301 U differential temperature control provides automatic, simple, safe and reliable operation of domestic solar water heating systems. The pump simply plugs into a switched outlet located on the controller unit, and the controller plugs into a wall outlet.

The LCD display gives the homeowner a variety of real time information including system temperatures at up to three separate locations.

Once the collector sensor is 16 degrees warmer than the storage tank sensor, the controller will power on the pump. The fluid is pumped up to and through the collector and then down into the heat exchanger (inside tank). As the collector loop fluid travels through the heat exchanger the heat is transferred into the storage tank water.

When the collector temperature is only 8 degrees warmer than the storage tank the controller will turn off the pump. If the storage tank reaches140 degrees

 Evacuated Tube Solar Collectors

Two (10-Tube Evacuated Tube) collector units will heat up to *50 gallons of water a day producing up to 30,000 BTU's; ideal for a two person home with a 55 gallon storage tank, additional panels can be added to your system to accommodate larger families.  Use three (10-Tube Evacuated Tube) collector units to upgrade to an 80-gallon system.

*Output varies depending on location, time of the year, and mounting angle.

 

ATS-10 our 10-Tube Evacuated Glass Collector

(SRCC CERTIFIED)

 
Tube size 1800 mm x 58 mm
Call for pricing and delivery options

 

 

ATS-20 our 20-Tube Evacuated Glass Collector

(SRCC CERTIFIED)

 
Tube size 1800 mm x 58 mm
Call for pricing and delivery options

 

 

ATS-30 our 30-Tube Evacuated Glass Collector

(SRCC CERTIFIED)

 
Tube size 1800 mm x 58 mm
Call for pricing and delivery options

 


 

 

Solar Storage Tanks

 

Solar Tank (Single Coil)

Techtanium Indirect Water Heaters

IMENSIONS Single Coil

TT-40

TT-55

TT-79

TT-119

DIAMETER

20.0”

20.0”

22.0"

28.0"

HEIGHT

45"

58"

71"

 

 

 

 

 

 

A Temp. & Press. Reilef Valve
B Domestic Hot Water Outlet
C Recirculation (TT-79, TT-119)
D Boiler Water Inlet (Supply)
E Control
F Domestic Cold Water Inlet
G Boiler Water Outlet (Return

 

 

 
 

PERFORMANCE RATINGS

TT-40

TT-55

TT-79

TT-119

CAPACITY (Gallons)

40

55

79

119

HEAT EXCHANGER SURFACE AREA SQ.FT.

14

14

26

26

RECOMM. FLOW RATE GPM (Boiler Water)

10

10

14

14

PRESSURE DROP PSI (Heat Exchanger)

2.3

2.3

11

11

FIRST HR. RATINGS GPH 90 DEGREE RISE

188

225

295

376

CONTINUOUS FLOW GPH 90 DEGREE RISE

160

187

240

293

FIRST HR. RATINGS GPH 70 DEGREE RISE

233

277

363

460

CONTINUOUS FLOW GPH 70 DEGREE RISE

205

239

308

377

BOILER SIZE BTU'S REQUIRED

120,000

140,000

180,000

220,000

NOTE: Above ratings based on boiler maintaining temp. of 180 degree's Fahrenheit

   

DIMENSIONS

TT-40

TT-55

TT-79

TT-119

DIAMETER

20.0”

20.0”

22.0"

28.0"

HEIGHT

45"

58"

71"

68"

SHIPPING WGHT (Lbs.)

124

143

243

355

PRODUCT SPECIFICATIONS

TT-40

TT-55

TT-79

TT-119

CONNECTIONS (inch) – All Tappings Are Female Thread Except Where Noted.*

TEMP. & PRESS. RELIEF VALVE

3/4”

3/4”

3/4”

3/4”

DOMESTIC HOT WATER OUTLET

3/4”

3/4”

1”

1”mpt

DOMESTIC COLD WATER INLET

3/4”

3/4”

1”

1”mpt

BOILER WATER OUTLET (RETURN)

1”

1”

1”

1”

CONTROL

1/2“

1/2“

1/2“

1/2“

BOILER WATER INLET (SUPPLY)

1”

1”

1”

1”

RECIRCULATON (TT-79, TT-119)

-

-

3/4”

3/4”

*TT-119 also supplied with adapter to increase from 1" Male to 1 1/4" Female, for Domestic Hot and Cold. TT-119 also has Inspection Port, with access near bottom of tank for removal of any sediment build up.

 

Solar Tank (Dual Coil)

 

DIMENSIONS Dual Coil

80

105

123

 

DIAMETER

23.63”

28.13”

28.13"

 

HEIGHT

71"

59.65"

72"

 

 

 

Advanced Thermal Solar (ATS) offers products that may require professional installation. (ATS) recommends hiring a HVAC professional trained in the service and repair of HVAC/R appliances. Parts sold by (ATS) may require specialized tools and/or procedures for safe and reliable operation of the effected systems. Buyer(s) specifically holds (ATS) harmless for injury, property damage, or other losses associated with the use of items purchased from (ATS). It is not the intention of (ATS) to encourage the servicing of HVAC/R appliances by untrained personnel, rather to "allow the public to purchase the necessary parts directly" for use by trained and/or licensed professionals.

 

Renewable Energy Long Island, promoting clean, sustainable energy use and generation for Long Island.

© 2008- 2012, Advanced Thermal Solar, LLC

Hit Counter by Digits

Make a Free Website with Yola.